1、CT增強(qiáng)掃描給藥方案及掃描時(shí)機(jī)——文獻(xiàn)回顧及應(yīng)用,Intravenous Contrast Medium Administration and Scan Timing at CT: Literature Review and Application,香港大學(xué)深圳醫(yī)院 何健龍,Adjustment is inevitable in certain situations including:,腎功能不全 Renal dysfuncti
2、on 肥胖 Obesity 血液循環(huán)異常 多層螺旋CT Multidetector CT 非常規(guī)靜脈入路 Venous Access Site,Goal: Achieve diagnostically adequate contrast enhancement,Cost:,Lowest radiation exposure (the shortest scan duration) Least amount of iodi
3、ne mass injected at the lowest acceptable rate for a given patient’s cardiovascular and renal function,造影劑動(dòng)力學(xué),Contrast Medium(CM) Pharmacokinetics,CT衰減 碘 X-ray能量,CT衰減與碘濃度成比例增加 Tube V. 越低,衰減比例越高 Care Mode 優(yōu)點(diǎn):血管 軟組織↑
4、 CM Radiation ↓ 缺點(diǎn):骨骼偽影↑ SNR ↓,造影劑動(dòng)力學(xué),Contrast Medium(CM) Pharmacokinetics,CT衰減 碘 X-ray能量,造影劑藥代動(dòng)力學(xué),Contrast Medium(CM) Pharmacokinetics,CM 體內(nèi)分布,主要與血流灌注(perfusion)相關(guān) 血液回流(recirculation)的影響 15s,造影劑藥代動(dòng)力學(xué),C
5、ontrast Medium(CM) Pharmacokinetics,CM 體內(nèi)分布,血流速度影響 峰值上升 高峰期縮短,影響增強(qiáng)效果和時(shí)機(jī)的因素,Factors Affecting Contrast Enhancement and Scan Timing,患者因素 Patient factors,Body Weight, Mass, Surface Area, and Mass Index,體重是最重要的影響參數(shù) 由于血容量
6、占體重比例的不同,CM的稀釋程度差異,患者因素 Patient factors,Body Weight, Mass, Surface Area, and Mass Index,調(diào)整比例1:1 linear scale e.g. doubling the iodine mass when the patient’s body weight doubles 兒童和肥胖患者血液含量的差別 Lean body weight, Su
7、rface area and Mass index 體表面積與體重直接相關(guān) (kg0.65),患者因素 Patient factors,Body Weight, Mass, Surface Area, and Mass Index,體重是調(diào)整CM用量的最主要參數(shù) 需要提高CM用量 和/或 濃度,以應(yīng)對(duì)體重的增加 以體重為基礎(chǔ)的調(diào)節(jié)比例基本正確,但須注意兒童和肥胖患者,患者因素 Patient factors,Cardiac Ou
8、tput and Cardiovascular Circulation,患者因素 Patient factors,Cardiac Output and Cardiovascular Circulation,是影響掃描時(shí)機(jī)的最主要參數(shù) 個(gè)體差異較大,因此需要bolus-tracking or test-bolus 器官差異:心臟、主動(dòng)脈、腎/ 肝臟 CO下降或循環(huán)障礙→Bolus延遲到達(dá)→ 排空延長(zhǎng)+強(qiáng)化上升,患者因素 Pat
9、ient factors,Other,性別:5-10%差異 年齡:>60 VS younger 10% stronger because of CO 身高:影響輕微 肝硬化:門脈期延遲并減弱 注射血管(intravenous access sites):中心靜脈入路 central venous injection 效果好但不安全,須減慢注射速度前臂靜脈須用低流速,強(qiáng)化高峰延遲2-4s,患者因素 Patient fac
10、tors,腎功能,對(duì)比劑腎病 contrast-induced nephropathy 尤其是腎功能不全的患者 Contrast-induced Nephropathy Consensus Working Panel guideline: <100 mL in patients with GFR <60 mL/min per 1.73 m2,對(duì)比劑因素 Contrast Medium Factors,注射時(shí)
11、間 Injection Duration,對(duì)強(qiáng)化程度和掃描時(shí)機(jī)均有明顯影響 太短——強(qiáng)化不足 太長(zhǎng)——不必要的組織及靜脈強(qiáng)化,影響觀察血管,浪費(fèi)CM,增加腎毒性,對(duì)比劑因素 Contrast Medium Factors,注射時(shí)間 Injection Duration,,,對(duì)比劑因素 Contrast Medium Factors,注射時(shí)間 Injection Duration,體型、目標(biāo)器官的血供、需要的強(qiáng)化程度 有時(shí)受注
12、射速率和對(duì)比劑濃度限制 計(jì)算方法A:根據(jù)體重計(jì)算適度強(qiáng)化所需碘用量選擇合適的注射速度及對(duì)比劑濃度得出注射時(shí)間,對(duì)比劑因素 Contrast Medium Factors,注射時(shí)間 Injection Duration,計(jì)算方法B:固定注射時(shí)間根據(jù)對(duì)比劑用量調(diào)整速度 好處是可以固定掃描時(shí)機(jī),不需重復(fù)計(jì)算scan delay,對(duì)比劑因素 Contrast Medium Factors,注射速度(流速) Injection
13、Rate,對(duì)比劑因素 Contrast Medium Factors,注射速度(流速) Injection Rate,提高流速用于可提高增強(qiáng)效果,但會(huì)縮小掃描時(shí)間窗(window for CT scanning),適合短程掃描,對(duì)比劑因素 Contrast Medium Factors,Fast injection for short scan duration 應(yīng)用于內(nèi)臟多期掃描 multiphasic imaging Slo
14、w injection for long scan duration,注射速度(流速) Injection Rate,對(duì)比劑因素 Contrast Medium Factors,對(duì)比劑濃度 Contrast Medium Concentration,Fixed CM Volumn,對(duì)比劑因素 Contrast Medium Factors,對(duì)比劑濃度 Contrast Medium Concentration,Fixed iodi
15、ne mass,e.g. 42g iodine for 70kg 4mL/s,300 mgI/mL at 140 mL 350 mgI/mL at 120 mL 400 mgI/mL at 105 mL,對(duì)比劑因素 Contrast Medium Factors,對(duì)比劑濃度 Contrast Medium Concentration,Effect of fixed iodine mass per second,300 mgI/
16、mL at 4mL/s vs 400 mgI/mL at 3mL/s,1.2g iodine / s,低濃度在CTA也許更好,因?yàn)闇p輕靜脈強(qiáng)化的背景干擾,尤其是下肢粘度低,系統(tǒng)壓力低,iodine delivery rate 碘劑給藥速度,對(duì)比劑因素 Contrast Medium Factors,對(duì)比劑濃度 Contrast Medium Concentration,提 示,為了提高對(duì)比劑給藥速
17、度,使用高濃度碘劑相當(dāng)于提高注射速率 在快速多排螺旋CT(MDCT),提高碘給藥速度可以使動(dòng)脈強(qiáng)化更明顯,動(dòng)脈期與延遲期分別更大 高濃度碘劑的潛在缺點(diǎn)在于高粘度,對(duì)比劑因素 Contrast Medium Factors,對(duì)比劑粘度 Viscosity,高濃度CM對(duì)增強(qiáng)效果的改善可能低于預(yù)期 受溫度影響,加熱至35°左右可降低粘度,改善患者耐受力 加溫可能會(huì)增加強(qiáng)化效果并使強(qiáng)化峰值提前,對(duì)比劑因素 Contrast
18、Medium Factors,沖管 Saline flush,提高CM集中度,改善增強(qiáng)效果 在胸部掃描中減輕無名靜脈及上腔靜脈引起的條形偽影 reduced streak artifact from dense contrast medium in thebrachiocephalic vein and superior vena cava on thoracic CT studies 減輕腎毒性 避免殘留CM堵塞靜脈留置管
19、 central line or PICC,對(duì)比劑因素 Contrast Medium Factors,沖管 Saline flush,沖管量決定于注射管容量contrast medium retained in the injection tubing 肘前靜脈至上腔靜脈的血容量 the peripheral venous space between the brachial vein and the superior ve
20、na cava 通常約20-30mL 對(duì)掃描時(shí)機(jī)的影響輕微,CT掃描因素 CT Scanning Factors,掃描時(shí)間 Scan Duration,掃描時(shí)間直接影響注射時(shí)間 Short scan < 10s Long scan including: 全外周血管造影 peripheral runoff CT angiography 冠脈造影 灌注掃描 perfusion acquisitions,,,CT掃
21、描因素 CT Scanning Factors,掃描方向 Scan Direction,一般為順造影劑流向 Craniocaudal Craniocaudal difference Caudocranial scanning Pulmonary CT angiography for the detection of pulmonary emboli Contrast material injection duration m
22、ay need to be increased,CT掃描因素 CT Scanning Factors,Determination of Contrast Material Arrival Time: Test Bolus vs Bolus-tracking Method,TB: 小劑量團(tuán)注 時(shí)間曲線 適當(dāng)延遲 BT: 正常注射 閾值監(jiān)控 延遲觸發(fā)掃描 前者更準(zhǔn)確,后者更有效率,CT掃描因素 CT Scanning Fact
23、ors,Determination of Contrast Material Arrival Time: Bolus-tracking,觸發(fā)閾值 enhancement threshold: 50-150 HU 觸發(fā)后延遲 post trigger delay,CT掃描因素 CT Scanning Factors,Determination of Contrast Material Arrival Time: Test Bolus
24、,Particularly for cardiac CT angiographic,CT掃描因素 CT Scanning Factors,只代表對(duì)比劑到達(dá)時(shí)間,不代表掃描延遲 對(duì)掃描延遲的個(gè)體化 individualize Scan dalay= Tarr + post trigger delay Post trigger delay depends on:injection duration, scan duration, h
25、emodynamics, location of target organ,Determination of Contrast Material Arrival Time: Time of arrival, Tarr,CT掃描因素 CT Scanning Factors,Determination of Contrast Material Arrival Time: Time of arrival, Tarr,常用Tarr 7–1
26、0 s for pulmonary artery 12–15 s for ascending aorta 15–18 s for abdominal aorta 30–40 s for hepatic parenchyma,CT掃描因素 CT Scanning Factors,TPEAK=TID+TARR-5or TPEAK=TID+TARR+25 TDELAY=TPEAK - 1/2TSD,掃描延遲 Scan delay
27、,Summary,使用較低的tube voltage可獲得更強(qiáng)的對(duì)比效果,或者減少對(duì)比劑用量 影響對(duì)比增強(qiáng)效果最重要的因素是患者體重 Injection duration 注射時(shí)間是最重要的注射器影響因素 Test bolus測(cè)得的TARR不能簡(jiǎn)單理解為掃描延遲,而是作為計(jì)算延遲的重要參數(shù) Scan delay=TARR + post trigger delay 推薦的scan delay計(jì)算公式為: TDELAY=TPEAK
28、 - 1/2TSD,Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches ; Kyongtae T.Bae, MD, PhD; July 2010, Radiology, 256, 32-61.,CT掃描因素 CT Scanning Factors,掃描延遲 Scan delay,Part two,
29、Clinical CT Applications,300 mgI/mL at 4mL/s vs 400 mgI/mL at 3mL/s,1.2g iodine / s,Iodine delivery rate 碘劑給藥速度,使用較低的tube voltage可獲得更強(qiáng)的對(duì)比效果,或者減少對(duì)比劑用量 影響對(duì)比增強(qiáng)效果最重要的因素是患者體重,Adjustment is inevitable in cert
30、ain situations including:,腎功能不全 Renal dysfunction 肥胖 Obesity 血液循環(huán)異常 多層螺旋CT Multidetector CT 非常規(guī)靜脈入路 Venous Access Site,Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches
31、 Kyongtae T.Bae, MD, PhD; Radiology, July 2010, 256, 32-61.,TARR at ascending aorta 降主動(dòng)脈,Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches Kyongtae T.Bae, MD, PhD; Radiolo
32、gy, July 2010, 256, 32-61.,Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches Kyongtae T.Bae, MD, PhD; Radiology, July 2010, 256, 32-61.,To achieve CT angiographic attenuatio
33、n of 250–350 HU for a 70-kg adult, 25 g of iodine injected at 1.6 g of iodine per second Caudocranial scanning direction TARR at ascending aorta 升主動(dòng)脈 A longer diagnostic delay will be required for a faster scan, a
34、longer injection, and brain-only CT angiography,Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches Kyongtae T.Bae, MD, PhD; Radiology, July 2010, 256, 32-61.,Enhancement of 1
35、50–200 HU in the thoracic vessels and cardiac chambers A shorter delay is typically used for greater thoracic cardiovascular enhancement, whereas a longer delay is used to increase the enhancement in the mediastinal sof
36、t tissue as well as the upper abdominal viscera.,Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches Kyongtae T.Bae, MD, PhD; Radiology, July 2010, 256, 32-61.,Diagnostic enha
37、ncement of pulmonary artery attenuation at 300–350 HU, with 1.4-1.6 g iodine/second Increased amount by 20%–40% of contrast medium for venography.,Intravenous Contrast Medium Administration and Scan Timing at CT: Consid
38、erations and Approaches Kyongtae T.Bae, MD, PhD; Radiology, July 2010, 256, 32-61.,Diagnostic enhancement of coronary attenuation at 300–350 HU Higher attenuation may lead to an underestimation of stenosis in smaller v
39、essels, whereas lower attenuation may cause a slight overestimation of stenosis Prospective cardiac-gated coronary CT angiography necessitates a longer injection duration for its longer scan duration,Intravenous Contras
40、t Medium Administration and Scan Timing at CT: Considerations and Approaches Kyongtae T.Bae, MD, PhD; Radiology, July 2010, 256, 32-61.,Injection rate is adjusted for the body weight, the injection duration is adjusted
41、for the scan duration. The total amount of C.M. volume is determined as the product of the injection rate and duration. CT scanner table may move faster than the contrast material bolus ("outrunning") Delib
42、erately reducing the scan speed would help prevent outrunning of the contrast material bolus Test-bolus recommended,,Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches Kyong
43、tae T.Bae, MD, PhD; Radiology, July 2010, 256, 32-61.,With multidetector CT, 50 HU is commonly considered to be a diagnostically appropriate level of hepatic phase enhancement. Be ware of obese patients for iodine dose
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 眾賞文庫僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 利用血管同步計(jì)劃控制增強(qiáng)ct掃描最佳時(shí)機(jī)的實(shí)驗(yàn)
- ct增強(qiáng)掃描 ppt課件
- ct增強(qiáng)掃描及其意義
- 胰腺CT增強(qiáng)掃描參數(shù)研究.pdf
- ct增強(qiáng)掃描中造影劑外滲
- ct增強(qiáng)掃描的臨床應(yīng)用ppt課件
- 頭頸部ct增強(qiáng)掃描的臨床價(jià)值
- ct增強(qiáng)掃描對(duì)腹部疾病的診斷價(jià)值
- 肝部CT增強(qiáng)掃描的小肝癌檢測(cè).pdf
- ct增強(qiáng)掃描的臨床準(zhǔn)備及臨床意義
- 早期肝膿腫CT三期增強(qiáng)掃描與MR.pdf
- CT動(dòng)態(tài)增強(qiáng)掃描診斷早期肺癌的研究.pdf
- 把握在線教育的時(shí)機(jī)
- 教育學(xué)生要把握“時(shí)機(jī)”
- 肝轉(zhuǎn)移癌超聲造影與CT增強(qiáng)掃描的對(duì)比研究.pdf
- CT靶掃描與三期增強(qiáng)掃描聯(lián)合應(yīng)用對(duì)肺結(jié)節(jié)的診斷價(jià)值.pdf
- 多層螺旋CT增強(qiáng)掃描區(qū)分肺癌腫塊與肺不張.pdf
- 孤立性肺結(jié)節(jié)ct動(dòng)態(tài)增強(qiáng)掃描的實(shí)用研究
- ct增強(qiáng)掃描在定性診斷中的價(jià)值ppt課件
- 法院調(diào)解的介入時(shí)機(jī)把握
評(píng)論
0/150
提交評(píng)論