1、,PROCEDURE,,,Make incision according to design requirement, and cut the mucoperiosteum. The design in Video is Triangle Lobe. Embedded incisions are usually on the crest of the alveolar ridge. Make vertical incisions fro
2、m top to bottom between 2 and 3, and then turn oblique down at interdental papilla , then horizontal incisions were made, and slightly close to the palate along the neck of maxillary lateral incisor to the gap.,1,PROCEDU
3、RE,The incision was extended to the Left maxillary central incisor.(The buccal-lingual bone needs to be preserved at least 1 mm, and the bone between the buccal-lingual bone and the adjacent teeth should be at least 1.5
4、 mm. The space of the missing teeth should be at least 7 mm.),1,,,Remove the mucoperiosteum from the subperiosteum with a stripper and expose the bone in the implant area.Grinding the bone tips with a ball drill (rot
5、ating speed 600 rpm), to shape the bone and to locate.,2,,,,Use pioneer drills to reach a predetermined depth (800 rpm). In general, the depth of the hole needs to be 1 mm deeper so that the cervical margin of the implan
6、t is 1 mm lower than the bone surface. Then measure the depth and direction of the implant with a directional bar.,3,,,,,After reaming step by step with stepped drill and finally reaching the requested diameter, the dept
7、h and direction of the hole can be measured by measuring rod, which should be slightly deeper than the 1mm of the implant.,3,,,,Use neck shaping drill for neck shaping (rotational speed: 300 rpm).,4,,,,Use tapping drill
8、for tapping (rotational speed: 15 rpm), but for patients with large aperture or osteoporosis, we can omit this step.,5,,,,,,,Rotate the implant manually or mechanically into alveolar bone. Note that the rotational speed
9、is 15 rpm and flushing is not necessary. It is important to note that the white bar mark must be aligned directly to the front.,6,,,,,,When the implant is in place, remove the implant carrier.,7,,,,,,,8,Screw the closed
10、screw manually or mechanically into the implant. The bone surface of the implant was perforated densely with a ball drill. Cover the cheek with the autologous bone debris which are collected during the preparation
11、 of the implant and demineralized frozen-dried bovine bone meal (Bio-Oss, Geistilich, Switzerland) with a thickness of 3-4 mm and then put an absorbable collagen film on the surface. (Bio-Gide, Geistilich, Switzerland).,
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 眾賞文庫僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
評論
0/150
提交評論