版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、結(jié)構(gòu)化布線系統(tǒng)基礎(chǔ)培訓(xùn)Basic Training of Generic Cabling System,Dätwyler 線纜系統(tǒng),革新的布線解決方案,2,© 2010/06 Dätwyler Ltd. Cables+Systems - CN,廣泛而專業(yè)的行業(yè)覆蓋,3,Generic datacabling systems (LAN),Carrier solutions (WAN),Safety Cab
2、lingAutomation cabling,Elevator cabling,Dätwyler 布線系統(tǒng)在世界各地的應(yīng)用,4,BMW, München,Airport, Frankfurt a.M.,Airport, Hongkong,Westin Hotel, Singapore,分支遍布世界各地,5,Europe Austria England Germany Netherlands Swit
3、zerland,Mid. East / Asia China Singapore,生產(chǎn)基地,6,,,Boudry/CH,,總部Altdorf/Switzerland,Shanghai&SuZhou/China,,通用布線系統(tǒng)(LAN),7,Multimedia solution catTV,FO cable,FO outlets,FO cablingclassicPre-assembledQBAC technolo
4、gy,FO patch cords,FO patch panels,Cu data cables,Cu oulets,Cu patch panels,Cu patch cords,Cu Modular Jacks,通信布線系統(tǒng)(WAN),8,Fibre Optic CablesEasy-BlowQBACOptofil-Safety,Components,Fibre Optic Patch Cords,安全線纜系統(tǒng),9,Safety
5、 Cables with circuit integrity,Strap/Single clamps,Fixing devices,Firestop systems,Cable trays andcable ladders,Multi cable support E30-E90,Sub-distribution,Emergeny lighting,電梯線纜,10,Suspension devices,Flexible elevato
6、r cable systems,Compensation weight,Harnessing,培訓(xùn)內(nèi)容,綜合布線系統(tǒng)銷售中幾個(gè)常見的問題如何配置一套綜合布線系統(tǒng)電子配線架系統(tǒng),綜合布線系統(tǒng)銷售中幾個(gè)常見的問題,兩個(gè)經(jīng)?;煜母拍睢獛捙c數(shù)據(jù)傳輸速率1G網(wǎng)絡(luò)的選型——超五類還是六類6A類系統(tǒng)的選擇——屏蔽還是非屏蔽,兩個(gè)經(jīng)?;煜母拍睢獛捙c數(shù)據(jù)傳輸速率,發(fā)送方,介質(zhì),接收方,,通信的三個(gè)要素,帶寬與數(shù)據(jù)傳輸速率
7、,帶寬(MHz)設(shè)備或介質(zhì)依照一定傳輸要求可以提供的工作頻率范圍數(shù)據(jù)傳輸速率(Mbps)數(shù)據(jù)傳輸系統(tǒng)數(shù)據(jù)吞吐量的描述,即在單位時(shí)間內(nèi)一個(gè)系統(tǒng)能傳遞的二進(jìn)制數(shù)位,10101…………100101011010001000101…………10010,,單位時(shí)間,帶寬與數(shù)據(jù)傳輸速率,帶 寬(MHz),數(shù)據(jù)傳輸速率(Mbps),頻率單位描述電信號(hào)和物理介質(zhì)有關(guān)不依賴于應(yīng)用,數(shù)據(jù)的速度系統(tǒng)吞吐量的描述和帶寬有關(guān)依賴于應(yīng)
8、用的編碼,幾種常見的誤解,我家里裝的是2兆帶寬的寬帶2兆帶寬的ADSL下載是256K的,所以網(wǎng)速等于帶寬除以8支持百兆網(wǎng)絡(luò)要用百兆帶寬的五類系統(tǒng),所以支持千兆網(wǎng)絡(luò)要用千兆帶寬的綜合布線系統(tǒng),21:18,16,事實(shí) 一,2兆ADSL中的2兆不是帶寬“xx帶寬的xx”只是誤傳的通俗叫法而非帶寬的真正意思我們常常把帶寬和寬帶混淆在一起,21:18,17,Bandwidth vs Broadband,事實(shí)二,如前述2兆不是指帶寬
9、2M和256K都是指數(shù)據(jù)傳輸速率兩者是bps和Bps的區(qū)別,是“位”和“字節(jié)”的差別,21:18,18,8 bit =1 Byte!,事實(shí)三,5類線纜有4對(duì)線,傳百兆網(wǎng)絡(luò)時(shí)只使用了2對(duì)通過有效的方式,可以物理編碼壓縮數(shù)據(jù)五類線4對(duì)線纜如全部雙向傳輸數(shù)據(jù),可以達(dá)到1000Mbps的傳輸速率,21:18,19,1000Mbps ≠ 1000MHz,1G的網(wǎng)絡(luò)的選型,目前主流網(wǎng)絡(luò)系統(tǒng)為千兆網(wǎng)絡(luò)系統(tǒng)構(gòu)建一套完整的千兆網(wǎng)絡(luò)需要
10、超五類以上的綜合布線作為支持這是否意味著六類系統(tǒng)激進(jìn)了?,21:18,20,超五類?六類?這是個(gè)問題!,從網(wǎng)絡(luò)的基礎(chǔ)說起,計(jì)算機(jī)網(wǎng)絡(luò)的發(fā)展歷程OSI七層模型網(wǎng)絡(luò)的分類拓?fù)浣Y(jié)構(gòu)以太網(wǎng)及CSMA/CD的訪問控制方式,計(jì)算機(jī)網(wǎng)絡(luò)的發(fā)展歷程,OSI七層模型,OSI七層模型,網(wǎng)絡(luò)的分類,局域網(wǎng)(LAN)幾米~10公里 小型機(jī)、微機(jī)大量推廣后發(fā)展起來的,配置容易、速率高,4M~2Gbps。位于一個(gè)建筑物或一個(gè)單位內(nèi),不存在循徑問題,
11、不包括網(wǎng)絡(luò)層城域網(wǎng)(MAN)10公里~100公里 對(duì)一個(gè)城市的LAN互聯(lián),采用IEEE802.6標(biāo)準(zhǔn),50Kbps~100Kbps,位于一座城市中廣域網(wǎng)(WAN)幾百~幾千公里。發(fā)展較早,使用專線構(gòu)成網(wǎng)狀結(jié)構(gòu),解決循徑問題,速率為9.6Kbps~45Mbps。如郵電部的CHINANET,CHINAPAC,CHINADDN互聯(lián)網(wǎng)并不是一種具體的網(wǎng)絡(luò)技術(shù),它是將不同的物理網(wǎng)絡(luò)技術(shù)按某種協(xié)議統(tǒng)一起來的一中高層技術(shù),拓?fù)浣Y(jié)構(gòu),
12、總線型網(wǎng)絡(luò),拓?fù)浣Y(jié)構(gòu),環(huán)形網(wǎng)絡(luò),拓?fù)浣Y(jié)構(gòu),星形網(wǎng)絡(luò),拓?fù)浣Y(jié)構(gòu),分布式網(wǎng)絡(luò),以太網(wǎng)及CSMA/CD的訪問控制方式,什么是以太網(wǎng)(Ethernet)以太網(wǎng)是70年代由Xerox開發(fā)出來的。現(xiàn)在已成了最流行的局域網(wǎng)標(biāo)準(zhǔn)。1980年,IEEE發(fā)布了IEEE 802.3規(guī)范,它的基礎(chǔ)就是以太網(wǎng)。不久,DEC,Intel和Xerox聯(lián)合開發(fā)和頒布了以太網(wǎng)規(guī)范2.0版本,它實(shí)質(zhì)上與IEEE802.3兼容,21:18,30,以太網(wǎng)及CSMA/CD的
13、訪問控制方式,以太網(wǎng)和物理層以太網(wǎng)及IEEE802.3定義了基帶信號(hào)速率為10M、100M這里被稱為10Base及100Base,分為以下幾種布線類型:10Base-2、10Base-5、10Base-T、100Base-T、100Base-F、1000Base-T、 1000Base-TX、 1000Base-F等等,以太網(wǎng)及CSMA/CD的訪問控制方式,以太網(wǎng)的訪問控制方式以太網(wǎng)是一種共享介質(zhì)的技術(shù),使用廣播的原理來傳送數(shù)據(jù)
14、,為了使用這種技術(shù),以太網(wǎng)使用載波監(jiān)聽多路訪問/碰撞檢測(Carrier Sense Multiple Access/Collision Detection, CSMA/CD)協(xié)議,允許網(wǎng)絡(luò)設(shè)備來協(xié)商傳輸數(shù)據(jù)的權(quán)利,21:18,32,以太網(wǎng)及CSMA/CD的訪問控制方式,,,,,,廣播就像高速公路,更多的接入點(diǎn)就意味著頻繁的碰撞發(fā)生必須使用CSMA/CD,以太網(wǎng)及CSMA/CD的訪問控制方式,網(wǎng)絡(luò)站點(diǎn)偵聽載波是否存在(即有無傳輸)并相
15、應(yīng)動(dòng)作的協(xié)議,被稱為載波偵聽多路訪問協(xié)議(carrier sense multiple access protocol)。當(dāng)兩臺(tái)計(jì)算機(jī)同時(shí)企圖通信并分別發(fā)送自己的幀時(shí),這種類型的網(wǎng)絡(luò)就會(huì)發(fā)生問題。這通常被稱為網(wǎng)絡(luò)沖突。這好比某人需要與15或20人同時(shí)對(duì)話,甚至用不同的語言。如果網(wǎng)絡(luò)正在發(fā)送數(shù)據(jù),而另一個(gè)網(wǎng)卡也開始發(fā)送數(shù)據(jù),就會(huì)產(chǎn)生沖突。每個(gè)網(wǎng)卡都受命等待一段隨機(jī)時(shí)間,在發(fā)送數(shù)據(jù)前重新偵聽。隨著網(wǎng)絡(luò)的擴(kuò)大和發(fā)送數(shù)據(jù)量的增加,產(chǎn)生沖突的
16、可能性也就越大。如果太多的計(jì)算機(jī)同時(shí)試圖進(jìn)行通信,網(wǎng)卡在發(fā)送數(shù)據(jù)時(shí)必然會(huì)產(chǎn)生沖突。這通常被稱為帶寬飽和,應(yīng)該盡量避免。,減少網(wǎng)絡(luò)沖突的方法,建立一種機(jī)制減少網(wǎng)絡(luò)中電腦通信碰撞產(chǎn)生劃分不同的子網(wǎng),使電腦相對(duì)孤立,并建立子網(wǎng)間通信的連接機(jī)制增加帶寬??!,21:18,35,減少網(wǎng)絡(luò)沖突的方法,,,,,,廣播就像高速公路,很多的接入點(diǎn)帶來頻繁的碰撞。但建設(shè)更寬的公路,就意味著通行速度更快,碰撞自然就大大減少。這就是堵和疏的區(qū)別?。?以太
17、網(wǎng)及綜合布線的關(guān)系,以太網(wǎng)設(shè)備與綜合布線相結(jié)合才能構(gòu)成一個(gè)網(wǎng)絡(luò)以太網(wǎng)的速度受到它所擁有的所有網(wǎng)絡(luò)組件的限制兩個(gè)不同的標(biāo)準(zhǔn)族IEEE802.3及IEC11801,互相依存,互相制約IEEE 802.3中對(duì)物理鏈路的定義決定了綜合布線的最低指標(biāo)IEC11801新的綜合布線指標(biāo),又做為IEEE802.3下一版本的參考,21:18,37,千兆以太網(wǎng)絡(luò)中的兩個(gè)標(biāo)準(zhǔn),國際電氣和電子工程師協(xié)會(huì)(IEEE) 802.3ab任務(wù)小組于1997
18、年發(fā)布了千兆以太網(wǎng)標(biāo)準(zhǔn)1000Base-T技術(shù)采用先進(jìn)的5級(jí)脈沖調(diào)幅(PAM)編碼方式,在4對(duì)超五類雙絞線上全雙工傳輸,即每對(duì)線在發(fā)送信號(hào)的同時(shí)又接收信號(hào)每對(duì)線上的傳輸速率是250Mbps,每對(duì)線所需帶寬不到80MHz,21:18,38,千兆以太網(wǎng)絡(luò)中的兩個(gè)標(biāo)準(zhǔn),2002年TIA/EIA-854頒布新的千兆以太網(wǎng)標(biāo)準(zhǔn)1000Base-TX技術(shù)使用4對(duì)線單工傳輸,其中兩對(duì)線用于發(fā)送,另外兩對(duì)線用于接收,每對(duì)線平均傳輸速率提高到50
19、0Mbps,在每對(duì)線上需要125MHz帶寬,需要更好的六類布線系統(tǒng)來支持,21:18,39,5級(jí)脈沖調(diào)幅(PAM)編碼方式,21:18,40,正常的方波電壓被壓縮調(diào)制成4個(gè)臺(tái)階分別對(duì)應(yīng)4個(gè)2位二進(jìn)制數(shù),1000Base-T的局限性,采用雙工傳輸技術(shù)會(huì)產(chǎn)生信號(hào)回波,導(dǎo)致信噪比(SNR)過高,網(wǎng)絡(luò)接受端無法獲得正常的信號(hào)。為了消除雙工傳輸帶來的回波影響,在網(wǎng)絡(luò)設(shè)備上必須加多一個(gè)數(shù)字信號(hào)處理器(DSP),專門處理網(wǎng)絡(luò)傳輸中產(chǎn)生的噪音D
20、SP價(jià)格不菲,約占千兆以太網(wǎng)卡成本的50%,所以這種可達(dá)到千兆傳輸?shù)某孱惒季€系統(tǒng)仍然很少或幾乎沒有在實(shí)際的網(wǎng)絡(luò)中加以應(yīng)用,21:18,41,1000Base-T的局限性,21:18,42,1000Base-Tx的優(yōu)勢,21:18,43,網(wǎng)絡(luò)設(shè)備制造成本較1000Base-T降低了大約50%,超五類?六類?,1000Base-Tx擁有更佳的抗干擾能力1000Base-Tx只能運(yùn)行在六類以上的綜合布線系統(tǒng)上 千兆網(wǎng)絡(luò)設(shè)備都將是100
21、0Base-Tx端口的即使運(yùn)行1000Base-T,六類線也能工作得更出色 六類綜合成本考慮,可節(jié)省15%!,21:18,44,1G網(wǎng)絡(luò)的選型結(jié)論,超五類系統(tǒng)只是“能夠”支持千兆以太網(wǎng)六類系統(tǒng)才是“真正有保證”地運(yùn)用千兆以太網(wǎng)比起超五類系統(tǒng),六類才是超值的選擇,21:18,45,6A類系統(tǒng)的決擇,21:18,46,對(duì)對(duì)屏蔽,非屏蔽,Vs,平衡電纜的原理,平衡電纜的物理特性雙絞電纜的分類雙絞電纜的平衡傳輸原理雙絞電纜的
22、傳輸性能特性阻抗(Impedance)回波損耗(Return Loss)衰減(Attenuation)近端串?dāng)_(NEXT)衰減串?dāng)_比(ACR)其他,,平衡電纜的物理特性,屏蔽雙絞線(S/UTP、F/UTP、U/FTP、S/FTP等)和非屏蔽雙絞線(U/UTP)則是典型的平衡電纜。而同軸電纜是典型的非平衡電纜。,每一對(duì)雙絞線都是由兩根具有絕緣保護(hù)層的銅導(dǎo)線按一定密度互相絞纏在一起形成的線對(duì)組成。常用的雙絞電纜是由4對(duì)雙絞線按一
23、定密度反時(shí)針互相扭絞在一起。雙絞線的纏繞密度和扭絞方向以及絕緣材料,直接影響它的特性阻抗、衰減和近端串?dāng)_。,雙絞電纜的分類,,非屏蔽雙絞線(U/UTP),普通屏蔽雙絞線(F/UTP),對(duì)對(duì)屏蔽雙絞線(S/FTP),高頻信號(hào)電磁波傳輸特性,短波3MHz—100m超短波30MHz—10m米波300MHz——1m分米波3000MHz——10cm1厘米波30GHz—1cm毫米波300GHz—1mm,21:18,50,,綜合布線范圍,需
24、要考慮的各個(gè)因素長線、分布參數(shù)、特性阻抗、匹配、反射、駐波、輻射感應(yīng)、 互感擾動(dòng)、幾何相關(guān)性、微帶線,數(shù)據(jù)電纜傳輸特性: 復(fù)雜頻率傳輸函數(shù),傳輸復(fù)雜頻率信號(hào),雙絞電纜的平衡傳輸原理,是指設(shè)備之間無用的電磁作用。對(duì)于布線系統(tǒng),電磁干擾會(huì)降低數(shù)據(jù)傳輸?shù)目煽啃裕黾诱`碼率。同軸電纜靠它特有的結(jié)構(gòu)屏蔽了外界干擾。而雙絞線則是靠每對(duì)線的兩根銅導(dǎo)線按一定間隔互相絞纏在一起來消除電磁干擾,這樣做有兩個(gè)好處。,電磁干擾(EMI),雙絞電纜的平衡
25、傳輸原理,如果雙絞線的絞距同電磁波的波長相比很小,我們可以認(rèn)為電磁場在第一個(gè)絞節(jié)內(nèi)產(chǎn)生的電流與第二個(gè)絞節(jié)內(nèi)產(chǎn)生的電流相同,這樣,電磁場對(duì)雙絞線中產(chǎn)生的影響可以相互抵消。雙絞線的絞距不能無限減小。這就是說,對(duì)于高頻電磁波(對(duì)應(yīng)波長較短),雙絞的作用降低。,減小外界電磁干擾(EMI),雙絞電纜的平衡傳輸原理,電纜中的電流產(chǎn)生電磁場。按照電磁感應(yīng)原理,我們可以確定電磁場的方向。第一個(gè)絞節(jié)內(nèi)的電流產(chǎn)生的電磁場與第二個(gè)絞節(jié)內(nèi)電流產(chǎn)生的電磁場大小
26、相等,方向相反,相加為零。這種情況只有在理想的雙絞電纜中才能發(fā)生。,減小線對(duì)之間的串音,實(shí)際上,理想的雙絞電纜是不存在的:首先,彎曲會(huì)造成絞對(duì)的松散;其次,電纜附近的任何金屬都會(huì)形成與雙絞線的電容耦合,使相鄰絞節(jié)內(nèi)的電磁場不再完全相反。如果上述情況發(fā)生,電纜就開始對(duì)外發(fā)射電磁波。同樣,在低頻情況下,問題不是很大,但是,頻率越高問題越嚴(yán)重。,雙絞電纜的傳輸性能——特性阻抗,導(dǎo)線的阻值與導(dǎo)線長度成正比,與導(dǎo)線截面成反比。阻抗中的“抗”指導(dǎo)
27、線所呈現(xiàn)的電磁和電容特性。一個(gè)給定的對(duì)稱電纜信道的特性阻抗極限不超過正常阻抗的15%。,影響特性阻抗的因素影響雙絞線的阻抗大小的因素除了銅芯材料外,還有D/d的比值和絕緣材料,以及雙絞線的纏繞密度和扭絞方向。而絕緣材料電氣特性的影響相對(duì)較小。見右圖。D/d的比值最容易受施工的影響:,雙絞電纜的傳輸性能——回波損耗,它是衡量信道阻抗一致性的一個(gè)重要指標(biāo),阻抗不連續(xù) 造成信號(hào)能量反射分布電容/電感變
28、化 對(duì)外輻射能量變化,雙絞電纜的傳輸性能——衰減,由于導(dǎo)線存在阻抗,阻礙信號(hào)的傳輸。當(dāng)信號(hào)頻率增高,由于趨膚效應(yīng)使電阻增大,又由于感抗增加、容抗減小,而使信號(hào)的高頻分量衰減加大。衰減與傳輸信號(hào)的頻率有關(guān),也與導(dǎo)線的傳輸長度有關(guān)。隨著長度增加,信號(hào)衰減也隨之增加。信號(hào)衰減用單位長度上信號(hào)減少的數(shù)量來度量(dB/m或分貝/米),表示源端信號(hào)傳遞到接收端信號(hào)強(qiáng)度的比率。,雙絞電纜的傳輸性能——串?dāng)_(XT),在4對(duì)雙紋電纜中,當(dāng)一
29、對(duì)線發(fā)送信號(hào)時(shí)在另一相鄰的線對(duì)中將收到信號(hào)。這種現(xiàn)象叫串?dāng)_。 雙絞線就是利用兩條導(dǎo)線絞合在一起后,因?yàn)橄辔幌嗖?80度的原因而抵消相互間的干擾的。絞距越緊則抵消效果越佳,也就越能支持較高的數(shù)據(jù)傳輸速率。,,,,,,??,雙絞電纜的傳輸性能——衰減串?dāng)_比,它是在同一頻率下鏈路的信號(hào)衰減與近端串?dāng)_損耗的比值,是確定可用帶寬的一種方法。衰減串?dāng)_比的值越大越好。該比值可用分貝(dB)表示,其值是近端串?dāng)_損耗和衰減的值之差。它代表了系統(tǒng)的
30、信噪比。,,ATTN,NEXT,,,ACR,。。。,,??,干擾,信息,6A系統(tǒng)的難題及一個(gè)新參數(shù),59,,6A系統(tǒng)是用來傳輸10GBase-T的以太網(wǎng),最新IEC11801要求超六類系統(tǒng)要達(dá)到500MHz的帶寬。這個(gè)時(shí)候,電磁波的波長只有60CM,和線對(duì)的絞距相比,已達(dá)到不可完全忽略的層度。干擾在相鄰絞節(jié)之間的抵消非常困難。而且除了纜線內(nèi)的相鄰線對(duì)之間的干擾外,相對(duì)來說距離比較遠(yuǎn)的相鄰纜線的干擾也對(duì)數(shù)據(jù)傳輸產(chǎn)生了威脅,所以從6A類開始
31、,業(yè)界標(biāo)準(zhǔn)提出了新的參數(shù)指標(biāo)ANEXT 。,外部串?dāng)_指標(biāo),60,,ANEST(Alien-NEXT)外部近端串?dāng)_,這個(gè)指標(biāo)早在五類線流行的時(shí)候就被提出過,同一捆線中一根線纜里的線對(duì)會(huì)給其他線纜里的線對(duì)帶來串?dāng)_影響。這種串?dāng)_通常稱為“外部串?dāng)_”,在UTP 中尤為明顯。但由于其測試的難度及測試的不確定性相當(dāng)大,且在當(dāng)時(shí)的帶寬頻率下未能對(duì)信號(hào)產(chǎn)生足夠的影響。,帶寬低 頻率低 衰減小 波長長 串?dāng)_小
32、 ACR信噪比高,帶寬高 頻率高 衰減大 波長短 串?dāng)_高 ACR信噪比低,顯然,普通UTP線纜的發(fā)展陷入了惡性循環(huán)之中!,61,,繁瑣的外部串?dāng)_指標(biāo)測試方案,減少有源線對(duì)間的互感應(yīng)擾動(dòng),62,,平行(累積)鄰近有源線對(duì)互感應(yīng)干擾累積增強(qiáng),雙絞(抵消)鄰近有源線對(duì)互感應(yīng)干擾積分抵消,對(duì)對(duì)屏蔽鄰近有源線對(duì)互感應(yīng)干擾屏蔽消除,隔離/垂直鄰近有源線對(duì)互感應(yīng)干擾隔離削
33、弱,減少外部線纜線對(duì)間的互感應(yīng)擾動(dòng),隔離,不規(guī)則外徑減少線對(duì)的平行可能,增大相鄰線纜中線對(duì)的距離,屏蔽鄰近線纜有源線對(duì)互感應(yīng)干擾屏蔽消除,6A線纜的另一種非主流思路,64,,帶寬高 頻率高 衰減大 波長短 串?dāng)_高 ACR信噪比低,,,試圖通過增大線徑達(dá)到減小衰減,而從矛盾的另一方面著手,6A系統(tǒng)的最終抉擇,65,,對(duì)對(duì)屏蔽線纜才應(yīng)該是6A線纜的最好解決方案,施工的難度施工的
34、隨機(jī)性生產(chǎn)的難度材料成本最終系統(tǒng)表現(xiàn),德特威勒F/FTP超6類線纜的優(yōu)勢,66,,Cat.6A,是7類線纜的簡化版,帶寬超過ICE11801:2008中 Class EA要求得益于對(duì)對(duì)鋁箔屏蔽加總鋁箔屏蔽的雙重屏蔽結(jié)構(gòu),只要接地良好,可以達(dá)到免測外部串?dāng)_指標(biāo)的最終目的NVP值達(dá)到80%由于使用屏蔽結(jié)構(gòu),昂貴的銅原材料反而減少了,產(chǎn)品編號(hào):1730117302,如何設(shè)計(jì)配置一套綜合布線系統(tǒng),結(jié)構(gòu)化的布線——綜合
35、布線綜合布線的發(fā)展綜合布線的特點(diǎn)綜合布線標(biāo)準(zhǔn)綜合布線的結(jié)構(gòu)信號(hào)的傳輸介質(zhì)與傳輸特性,結(jié)構(gòu)化的布線——綜合布線,綜合布線系統(tǒng)是無源的綜合布線系統(tǒng)需要和有源設(shè)備構(gòu)成網(wǎng)絡(luò),常用的有源設(shè)備有HUB/SWITCH/PC/SERVER/ROUTER綜合布線本質(zhì)是星形的、分布式的結(jié)構(gòu)構(gòu)以適應(yīng)布線系統(tǒng)的要求,綜合布線的特點(diǎn),結(jié)構(gòu)化布線系統(tǒng)具有以下特點(diǎn): 兼容性:靈活性:開放性:模塊化:擴(kuò)展性:經(jīng)濟(jì)性
36、:,綜合布線的特點(diǎn)帶寬與投資保護(hù),綜合布線標(biāo)準(zhǔn),ISO/IEC 11801國際標(biāo)準(zhǔn)組織(ISO)和國際電子技術(shù)委員會(huì)(IEC)發(fā)布的標(biāo)準(zhǔn)——ISO/IEC 11801。該標(biāo)準(zhǔn)提出綜合布線結(jié)構(gòu)、規(guī)模、部件傳輸性能定義,安裝規(guī)范和測試條例。,CENELEC EN50173歐洲EN50173標(biāo)準(zhǔn)和ISO/IEC 11801標(biāo)準(zhǔn)是一致的,但更嚴(yán)格。,TIA/EIA 568商用建筑電信布線標(biāo)準(zhǔn),定義了綜合布線設(shè)計(jì)、設(shè)備和部件的有關(guān)規(guī)范,
37、以及5類傳輸性能的安裝和測試。2000年發(fā)布一個(gè)整個(gè)標(biāo)準(zhǔn)的全新增補(bǔ)版TIA/EIA 568B,它將所有的變更之處和影響“A”版的TSB歸并進(jìn)去,并推薦使用5e類線。,綜合布線其他相關(guān)標(biāo)準(zhǔn),TIA/EIA 569有關(guān)布線通路設(shè)計(jì)(天花板上或地板下的管道及其支撐系統(tǒng))和相關(guān)安裝的商用建筑標(biāo)準(zhǔn)。明確規(guī)定了通信間、設(shè)備間和入口設(shè)備的設(shè)計(jì)。TIA/EIA 606商用建筑電信基礎(chǔ)結(jié)構(gòu)的管理標(biāo)準(zhǔn)。包括對(duì)標(biāo)定、色碼和數(shù)據(jù)記錄的明確規(guī)定。電信安
38、裝和綜合布線系統(tǒng)文檔的基本要求。TIA/EIA TSB67非屏蔽雙絞線布線系統(tǒng)現(xiàn)場測試的傳輸性能規(guī)定,包括對(duì)手持式線纜測試儀器更加嚴(yán)格的要求。AWG(American Wire Gauge):測量導(dǎo)線直徑的美國線規(guī)。TSB568A/B:模塊化插座和插頭的接線方案。GB/T 50311—2000《建筑與建筑群綜合布線系統(tǒng)工程設(shè)計(jì)規(guī)范》GB/T 50312—2000《建筑與建筑群綜合布線系統(tǒng)工程施工及驗(yàn)收規(guī)范》。這
39、兩個(gè)標(biāo)準(zhǔn)的出臺(tái)標(biāo)志了綜合布線在我國也走向正規(guī)化、標(biāo)準(zhǔn)化。,綜合布線結(jié)構(gòu),基干(垂直)布線,設(shè)備間子系,建筑群子系統(tǒng),管理子系統(tǒng),水平子布線,工作區(qū)子系統(tǒng),綜合布線原理圖,各個(gè)布線系統(tǒng)部分可連接成如下原理圖,綜合布線典型設(shè)置拓?fù)鋱D,綜合布線部件的典型設(shè)置拓?fù)鋱D如下圖所示。配線架可以設(shè)置在設(shè)備間或配線間中。電纜、光線根據(jù)安裝條件敷設(shè)在管道電纜溝、電纜豎井、電纜托架、線槽、暗管等通道中,其設(shè)計(jì)和安裝應(yīng)符合國家有關(guān)標(biāo)準(zhǔn)的規(guī)定。允許將不同配線
40、架的功能組合在一個(gè)配線架中,如下圖中,建筑物中的建筑群配線架(MD)和樓宇過渡配線架(BD)就組合在一個(gè)配線架中,樓宇過渡配線架(BD)和水平配線架(FD)的功能也可組合在一個(gè)配線架中。,綜合布線設(shè)計(jì)注意事項(xiàng),跳插線、工作區(qū)電纜、光纜應(yīng)符合設(shè)計(jì)指標(biāo)的有關(guān)要求。這些電纜的衰減允許比水平電纜的衰減大50%。特性阻抗為100Ω的雙絞電纜及連接硬件的性能分為下列幾類:3類 傳
41、輸性能支持16MHz以下的應(yīng)用;4類 傳輸性能支持20MHz以下的應(yīng)用;5類/超5類 傳輸性能支持100MHz以下的應(yīng)用;6類 傳輸性能支持250MHz以下的應(yīng)用。6A類 傳輸性能支持500MHz以下
42、的應(yīng)用。7類 傳輸性能支持600MHz以下的應(yīng)用。7A類 傳輸性能支持1.0GHz以下的應(yīng)用。在同一個(gè)布線通道中使用了不同類別的器件時(shí),該通道的傳輸性能由最低類別的器件決定。在一個(gè)布線通道,不應(yīng)混用標(biāo)稱特性阻抗不同的電纜,也不能混用光纖芯徑不同的光纜。在布線系統(tǒng)中,不應(yīng)有橋接抽頭(T型接頭)。,信號(hào)的
43、傳輸介質(zhì)及傳輸特性,鏈路的分類及定義銅纜的分類平衡電纜的傳輸特性光纖及其傳輸特性,鏈路(Link)的定義,,光纖的尺寸,,,125 um,,,,,62.5 um,,,,包層,纖芯,多模光纖,,,,,,,,8.3 um,,,包層,纖芯,單模光纖,125 um,與頭發(fā)絲比較,,,,85 um,,,,,,模場直徑,模場直徑,幾類光纖的簡要特點(diǎn),單模光纖和多模光纖,單模光纖和多模光纖特點(diǎn)比較,光纖的傳輸特性——衰減,光能經(jīng)過光纖傳輸后的減
44、弱稱為光纖的衰減或損耗。它直接影響著綜合布線的傳輸距離。光纖衰減定義為長度為L(km)的光纖輸出端光功率Po與輸入端光功率Pi的比值。用分貝(dB)表示 ? =(10 / L)Log10 pi / po (dB/Km)如光功率經(jīng)過一公里長的光纖傳輸后,輸出光功率是輸入的一半,則此光纖的衰減為3dB/km 引起光纖衰減的主要原因有以幾種:,,吸收損耗,散射損耗,,,本征材料吸收損耗不純物吸收損耗 OH離子吸
45、收損耗,瑞利散射損耗結(jié)構(gòu)不均勻散射損耗,光波長與衰減的關(guān)系,在某些波長附近光纖的損耗最低。這些波段稱為光纖的低損耗“窗口”或“傳輸窗口”多模光纖一般有兩個(gè)窗口,即兩個(gè)最佳的光傳輸波長,分別是850nm和1300nm;單模光纖也有兩個(gè)窗口,分別是1310nm和1550nm。,光纖的傳輸特性——帶寬與色散,光脈沖經(jīng)過光纖傳輸之后,不但幅度會(huì)因衰減而減小,波形也會(huì)發(fā)生愈來愈大的失真,集中的光能(如光脈沖),經(jīng)過光纖傳輸后在末端能量分
46、散,發(fā)生脈沖展寬現(xiàn)象,如下圖所示。,可見,兩個(gè)原本有間隔的光豚沖,經(jīng)過光纖傳輸之后產(chǎn)生了重疊。為避免重疊的發(fā)生,輸入脈沖有一最高速率限制。相鄰兩個(gè)脈沖雖重疊仍能區(qū)別開時(shí)的最高脈沖速率為該光纖線路的最大可用帶寬。脈沖的展寬不僅與脈沖的速度有關(guān),也與光纖的長度有關(guān)。所以,用光纖的傳輸信號(hào)速率與其傳輸長度的乘積來描述光纖的帶寬特性,其代表符號(hào)為B·L,單位為GHz·km或MHz·km。其含義是對(duì)某個(gè)B·
47、L值而言。當(dāng)距離增長時(shí),允許的帶寬就得相應(yīng)地減小。,輸入端脈沖,輸出端脈沖,測試,目測光功率計(jì)確定光纖部分的損耗(dB)以適當(dāng)?shù)牟ㄩL和適當(dāng)?shù)墓饫w連接器測試 OTDR(Optical Time Domain Reflectometer)精確知道光纖的性能從低成本的故障檢查器到基于電腦的功能完善的儀器都有,產(chǎn)品應(yīng)用工程案例,方案設(shè)計(jì)實(shí)施設(shè)計(jì)驗(yàn)收,產(chǎn)品應(yīng)用工程案例——方案設(shè)計(jì),需求分析需求分析是綜合布線的前提,根據(jù)客戶的需求
48、來設(shè)計(jì)你的綜合布線工程。設(shè)計(jì)原則先進(jìn)性科學(xué)性經(jīng)濟(jì)性實(shí)用性 總體設(shè)計(jì)總體設(shè)計(jì)是綜合布線系統(tǒng)設(shè)計(jì)中的一個(gè)關(guān)鍵部分,可以說它是綜合布線系統(tǒng)的框架,今后的各項(xiàng)均應(yīng)以總體設(shè)計(jì)為基礎(chǔ)。,結(jié)構(gòu)化布線系統(tǒng)的總體設(shè)計(jì),總體設(shè)計(jì)的依據(jù):建筑位置、用途、規(guī)模、形象定位等甲方需求:包括書面的、口頭的根據(jù)收集的信息制定各子系統(tǒng)布線級(jí)別建筑群子系統(tǒng)設(shè)備間子系統(tǒng)垂直子系統(tǒng)管理間子系統(tǒng)水平布線子系統(tǒng)工作區(qū)子系統(tǒng),方案
49、妥協(xié)與退讓——以節(jié)省并保護(hù)投資為目的,采用高級(jí)別線纜配低級(jí)別接插件舉例:1、采用7類線搭配超6類接插件 2、采用6類線搭配超5類接插件優(yōu)勢:線纜為高級(jí)別,保護(hù)了投資劣勢:整個(gè)系統(tǒng)只能按低級(jí)別驗(yàn)收采用用處不同的信息點(diǎn)不同級(jí)別布線舉例:1、數(shù)據(jù)點(diǎn)采用6類線,語音點(diǎn)采用超5類線 2、內(nèi)網(wǎng)用屏蔽線,外網(wǎng)用非屏蔽線優(yōu)勢:滿足不同信息點(diǎn)各自的需求劣勢:不同級(jí)別的信息點(diǎn)相互冗余不足,管理復(fù)雜語音水平線
50、端接采用110配線架優(yōu)勢:節(jié)省了投資劣勢:失去了部分冗余,管理不方便,跳線復(fù)雜,21:18,89,綜合布線方案,,,,,,,,,MMOF or SMOF,,,,MD,BD,FD,WA,25P OR 100P,4P,4P,4P,,,,綜合布線系統(tǒng)四級(jí)結(jié)構(gòu)示意圖,MMOF or SMOF,常見的信息點(diǎn)(TO)的分布舉例,明確用途明確家具布局按裝修圖紙結(jié)合實(shí)際需求分布開放式辦公室按15~20平米2個(gè)信息點(diǎn)配置酒店客房2個(gè)數(shù)據(jù)點(diǎn),
51、2個(gè)語音點(diǎn),1門并聯(lián)電話配置普通辦公室每張辦公桌2個(gè)信息點(diǎn)(如有內(nèi)外網(wǎng)則3個(gè))領(lǐng)導(dǎo)辦公室領(lǐng)導(dǎo)辦公桌3個(gè)信息點(diǎn)(如有內(nèi)外網(wǎng)則4個(gè))會(huì)議室按大小適當(dāng)配置,預(yù)留AP教室、實(shí)驗(yàn)室2~4個(gè)信息點(diǎn)宿舍、住宅房間宿舍2個(gè)信息點(diǎn),住宅每個(gè)房間4個(gè),客廳6個(gè)公共區(qū)適當(dāng)預(yù)留,預(yù)留AP,實(shí)施設(shè)計(jì),綜合布線管理標(biāo)記綜合布線管理標(biāo)記是管理綜合布線的一個(gè)重要組成部分,統(tǒng)一標(biāo)記的規(guī)則能方便施工管理和做文檔。完整的標(biāo)記應(yīng)提供以下信息:建筑物
52、名稱、位置、起始點(diǎn)和功能等。,實(shí)施設(shè)計(jì),XZ: 行政中心樓BD1F:底樓的BD(Building Distributor)FD2F:二樓的FD(Floor Distributor)2F001:2F代表二樓,001表示線纜序號(hào)ZG-2 :ZG代表主干電纜,2是線纜序號(hào),編號(hào)規(guī)則:,XZ,實(shí)施設(shè)計(jì),2F001 ~~ 2F024,ZG-2 (主干電纜),,1、RJ-45配線架(24口),2F025
53、 ~~ 2F048,此配線架接口呈“一”字排開,分4塊,每塊6口。所以,線纜編號(hào)每24個(gè)為一個(gè)配線架;主干電纜(25對(duì)UTP)單獨(dú)占一塊共6口,編號(hào)示意圖如右圖所示。,配線架的標(biāo)記:,實(shí)施設(shè)計(jì),配線架的標(biāo)記:,,,,,2F001 ~ 2F025,2F026 ~ 2F050,2F101~ 2F125,2F126 ~ 2F050,2F051 ~ 2F075,2F076 ~ 2F100,,ZG-2 (主干電纜),2、110
54、配線架(200對(duì)),此配線架分左右兩大塊,每塊有4條打線槽,每條能打25對(duì)線(即6根4對(duì)UTP線)。所以,線纜編號(hào)示意圖如右圖所示。,具體設(shè)計(jì),信息點(diǎn)分布表在具體的工程實(shí)施設(shè)計(jì)前需要了解具體的信息點(diǎn)分布情況,包括工程的各個(gè)布線區(qū)域。這可從用戶處獲取或根據(jù)用戶要求而設(shè)計(jì)。綜合布線拓?fù)鋱D根據(jù)信息點(diǎn)分布表并結(jié)合布線場所實(shí)際情況,可以畫出綜合布線拓?fù)鋱D,這不僅對(duì)于施工具有很大的指導(dǎo)意義,也大大方便了施工完成后的維護(hù)。布線材料清單
55、可根據(jù)綜合布線拓?fù)鋱D(或結(jié)合信息點(diǎn)分布表),來決定需要多少布線材料,此表即方便管理,又方便工程結(jié)算。信息點(diǎn)分布平面設(shè)計(jì)圖用于施工的信息點(diǎn)分布平面設(shè)計(jì)要完成:1.信息點(diǎn)的數(shù)量2.信息點(diǎn)的定位及其標(biāo)號(hào)3.信息點(diǎn)水平布線的走向,具體設(shè)計(jì),水平布線用線的估算在具體的工程實(shí)施設(shè)計(jì)前需要了解大致線纜的采購用量,但面對(duì)一個(gè)龐大的綜合布線系統(tǒng),測算每一個(gè)信息點(diǎn)的用線量是不切實(shí)際的。在實(shí)際工程預(yù)算中我們使用以下的公式估算每個(gè)樓層的水
56、平布線用線量,樓層水平布線長度=(最遠(yuǎn)的信息點(diǎn)+最近的信息點(diǎn))÷2×1.1+2×樓層高度,接插件的計(jì)算每層的點(diǎn)位除以24,采用進(jìn)位法,理線架等于配線架,主干的估算樓層高度差加上弱電井道與機(jī)房的水平距離加10米左右的預(yù)留,驗(yàn)收,綜合布線的測試驗(yàn)收分兩種:驗(yàn)證測試和認(rèn)證測試;驗(yàn)證測試一般是在施工過程中施工人員邊施工便測試,但通常只注重連接性能;認(rèn)證測試則是對(duì)綜合布線依照某一標(biāo)準(zhǔn)進(jìn)行逐項(xiàng)比較,以確
57、定綜合布線是否全部達(dá)到設(shè)計(jì)要求,包括連接性能測試和電氣性能測試。,驗(yàn)收,認(rèn)證測試的方法——永久鏈路測試,專業(yè)認(rèn)證測試儀,20年質(zhì)保,認(rèn)證的布線系統(tǒng)定義為:綜合布線系統(tǒng)完全由經(jīng)過認(rèn)可的無源連接產(chǎn)品構(gòu)成。認(rèn)證的綜合布線系統(tǒng)不包括任何有源設(shè)備、公共網(wǎng)絡(luò)接口或終端設(shè)備。整個(gè)綜合布線系統(tǒng)必須由授權(quán)的認(rèn)證安裝商安裝。在安裝中使用的設(shè)備、檢測儀器,都根據(jù)國家標(biāo)準(zhǔn)規(guī)定進(jìn)行校準(zhǔn)和測試。布線系統(tǒng)經(jīng)驗(yàn)收測試符合相關(guān)國際標(biāo)準(zhǔn),并須辦理有關(guān)手續(xù),而
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 眾賞文庫僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 服務(wù)器、網(wǎng)絡(luò)布線基礎(chǔ)
- 綜合布線基礎(chǔ)知識(shí)培訓(xùn)
- 布線標(biāo)準(zhǔn)簡述及建筑物布線基礎(chǔ)設(shè)施標(biāo)準(zhǔn)
- 1.綜合布線基礎(chǔ)知識(shí)介紹
- 布線器材與布線工具
- 綜合布線模板vcom布線產(chǎn)品
- 綜合布線模板vcom布線產(chǎn)品
- 綜合布線辦公樓布線方案
- pcb板基礎(chǔ)知識(shí)布局原則布線技巧設(shè)計(jì)規(guī)則
- 系統(tǒng)布線
- 布線預(yù)算
- 綜合布線
- 綜合布線
- 綜合布線-11綜合布線實(shí)際案例分析
- 布線電纜橋架設(shè)計(jì)技術(shù)_綜合布線
- 小區(qū)綜合布線系統(tǒng)綜合布線課程設(shè)計(jì)
- 雙絞線布線標(biāo)準(zhǔn)
- 綜合布線系統(tǒng)
- 布線工作師
- 任務(wù)9 綜合布線系統(tǒng)工程光纜布線敷設(shè)
評(píng)論
0/150
提交評(píng)論